[SOURce:]ARB:SEQuence:STEP:CURRent:STEP:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:STEP:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:STEP:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:STEP:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:STEP:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:STEP:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:STEP:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:STEP:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the delay in seconds after the trigger is received, but before the step occurs for Arb sequence
steps.
Parameter Typical Return
0 – 262.144 | MIN | MAX, *RST 0 <start time>
Step 0 - 99, *RST 0 (none)
Programs a start time for the current step: ARB:CURR:STEP:STAR:TIM 1,(@1)
Programs a start time for the voltage step: ARB:VOLT:STEP:STAR:TIM 1,(@1)
Programs a start time for the power step: ARB:POW:STEP:STAR:TIM 1,(@1)
Programs a start time for the resistance step: ARB:RESISTANCE:STEP:STAR:TIM 1,(@1)
Programs a start time for step 0: ARB:SEQ:STEP:CURR:STEP:STAR:TIM 1, 0,(@1)