EasyManua.ls Logo

Keysight N9020B - Delta Marker (Reset Delta); Marker Settings Diagram; All Markers Off; Couple Markers

Keysight N9020B
2530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Short-Range Comms & IoT Mode
3.10 Spurious Emissions Measurement
Backwards
Compatibility
SCPI
:CALCulate:SPURious:MARKer[1]|2|…|12:STATe OFF | ON | 0 | 1
:CALCulate:SPURious:MARKer[1]|2|…|12:STATe?
Delta Marker (Reset Delta)
Pressing this control has exactly the same effect as selecting Delta in "Marker
Mode" on page 1420. The selected marker becomes a Delta Marker. If the selected
marker is already a Delta marker, the reference marker is moved to the current
position of the selected marker, thus resetting the Delta to zero.
Marker Settings Diagram
Lets you configure the Marker system using a visual utility.
All Markers Off
Turns off all markers.
Remote
Command
:CALCulate:SPURious:MARKer:AOFF
Example
:CALC:SPUR:MARK:AOFF
Couple Markers
When this function is ON, moving any marker causes an equal X-Axis movement of
every other marker that is not OFF. By “equal X-Axis movement” we mean that we
preserve the difference between each marker’s X-Axis value (in the fundamental x-
axis units of the trace that marker is on), and the X-Axis value of the marker being
moved (in the same fundamental X-Axis units).
This may result in markers going off screen.
Remote
Command
:CALCulate:SPURious:MARKer:COUPle[:STATe] ON | OFF | 1 | 0
:CALCulate:SPURious:MARKer:COUPle[:STATe]?
Example
:CALC:SPUR:MARK:COUP ON
:CALC:SPUR:MARK:COUP?
Preset
OFF
Preset by Mode Preset and All Markers Off
State Saved Saved in instrument state