3 Short-Range Comms & IoT Mode
3.7 ACP Measurement
# Item Result Unit, if any
32 Upper offset B Absolute power dBm
... ...
When "Max Num of Offsets" on page 902 is 6, returns 48 results (Offset A-F: 48 = 24
+ 4*6) and when set to 12, returns 72 results (Offset A-L: 72 = 24 + 4 * 12)
If any result is not available, -999.0 is returned
Measurement Type = Power spectral density reference
For the trace specified by "Measure Trace" on page 1508, returns comma-separated
scalar results in the following order:
# Channel Item Unit, if any
1 Channel (1) Relative power dB
2 Channel (1) Absolute power dBm/Hz or dBm/MHz*
3 Channel (2) Relative power dB
4 Channel (2) Absolute power dBm/Hz or dBm/MHz*
... ...
23 Channel (12) Relative power dB
24 Channel (12) Absolute power dBm/Hz or dBm/MHz*
25 Lower offset A Relative power dB
26 Lower offset A Absolute power dBm/Hz or dBm/MHz*
27 Upper offset A Relative power dB
28 Upper offset A Absolute power dBm/Hz or dBm/MHz*
29 Lower offset B Relative power dB
30 Lower offset B Absolute power dBm/Hz or dBm/MHz*
31 Upper offset B Relative power dB
32 Upper offset B Absolute power dBm/Hz or dBm/MHz*
... ...
When "Max Num of Offsets" on page 902 is 6, returns 48 results (Offset A-F: 48 = 24
+ 4*6) and when set to 12, returns 72 results (Offset A-L: 72 = 24 + 4 * 12)
*The unit is determined by "PSD Unit" on page 955: DBMHZ or DBMMHZ
If any result is not available, -999.0 is returned