392 Keysight N9927-90001 User’s Guide
Channel Scanner (Option 312)
How to Set Up Channel Scanner
Figure 22-19 FieldFox Antenna Editor
How to use the Antenna/Cable Editor
—Press New then Yes to clear all data from the existing Antenna or Cable
table and reset header information to default settings.
—Then Edit Antenna
or Edit Cable to open the Antenna / Cable Editor.
— Then use the arrows to select a field.
— To edit header information, press Edit
then modify the selected field
using the FieldFox labeler.
——Description: Enter a description for the antenna or cable
correction table. This is NOT the filename used to save the file.
——Antenna Unit (Rcvr-side Antennas only): Units in which the
measurement will be displayed. Select NONE (default setting)
to select from standard Channel Scanner Units on the Scale
menu. Learn how in “Scale and Units” on page 151.
——Choose from: dB μV/m - (dB micro Volts per meter), dB μA/m
- (dB micro Amps per meter), dBG (gauss), dBpT (tesla).
——Freq Interpolation: Set to LINear and can NOT be edited.
— To edit Frequency/Value pairs, enter numbers using the numeric
keypad, and a frequency suffix when necessary.
——For both Cable and Antenna correction, Positive numbers
indicate loss (we need ADD something positive to compensate
for it), and Negative is indicative of some existing gain.