EasyManuals Logo
Home>Kidde>Control Panel>VM-1R

Kidde VM-1R User Manual

Kidde VM-1R
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Initiating
Devices
SUBMIT
     
VM Series
Head End
14
Intelligent initiating devices
VM
Intelligent Initiating Devices
SERIES
KI-Series
Intelligent
Detectors
Optical and combination detectors
KI-Series optical detectors continuously adjust their sensitivity based on
fluctuating environmental conditions such as the presence of dirt, smoke,
humidity, or changes in temperature and notify the control panel of any changes
in sensor sensitivity. When the detector has adjusted its sensitivity to its
maximum limit, it issues a dirty sensor warning, allowing enough of a margin
for maintenance personnel to clean the detector before it goes into trouble
condition. These detectors perform comprehensive self-diagnostics and store
these details in their on-board memory.
Optical Smoke Detector
KI-PD Optical Smoke Detector uses an optical sensing chamber to detect smoke. The
detector analyzes data gathered by the sensor to determine when an alarm is initiated.
Thanks to its high-performance optical sensing chamber, the KI-PD responds quickly and
reliably to a wide range of fire types, especially slow burn ing fires fuelled by combustibles
typically found in modern multi-use buildings. The KI-PD detects extremely small particles
and triggers an alarm at the first sign of smoke.
KI-PD Intelligent Optical Smoke Detector Data Sheet K85001-0646
Optical Smoke/Fixed Temperature Heat Detector
KI-PHD Optical/Fixed Temperature Detector houses an optical sensing chamber that
detects smoke, as well as a fixed-temperature sensor that detects heat. The detector
analyzes data from both sensors to determine when an alarm is initiated. This combines
the suitability of optical sensing for slow burning fires with the sensitivity of fixed-temper-
ature detection for fast flaming fires, arriving at a solution that responds reliably to the
widest range of fire types. A sophisticated algorithm processes data from both sensors
over time so that an alarm is only reported when conditions precisely match the signa-
ture of a fire. This eliminates the shortcomings of single-sensor optical and heat detec-
tion, and significantly reduces the risk of nuisance alarms.
KI-PHD Intelligent Optical/Fixed Temperature Detector Data Sheet K85001-0650

Questions and Answers: