5-8
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-19 for the procedure for ac-
cessing the turntable motor.
1. Unplug microwave oven or disconnect
power.
2. Disconnect one of the wire connectors
from the motor terminals.
3. Set the ohmmeter to the R x 1K scale.
4. Touch the ohmmeter test leads to the turn-
table motor terminals. The meter should
indicate approximately 2450 .
TURNTABLE MOTOR