13
Controller cover
Socket bolt
(gear case side)
Ground line
Cover belt
Remove the lead
wire in advance
Plate screw
Plate
Pan-head
machine screw
Inverter
Socket bolt
Limit switch
O ring
(3) Remove the socket bolt (gear case side)
securing the cover belt, and remove the
controller cover from the gear case.
The controller cover can be removed with the cover belt
attached.
(4) Remove the lead wire and connector
between the plate, main body, and inverter,
and remove the plate and inverter.
Loosen the 3 Plate screws to remove the plate.
Loosen the 4 pan-head machine screws of the inverter to
remove it.
Make a note of the locations of the lead wire connections
that will be referred to upon reassembly.
(5) Remove the limit switch as required.
Remove the connector of the limit switch rst.
Remove it carefully by holding the connector of the limit
switch side.
Loosen the 3 socket bolts to remove the limit switch
(replace the O ring attached to the shaft with a new part
upon reassembly).
Be careful when removing the limit switch because it may
be damaged if handled in a wrong way.
Do not disassemble the limit switch.
Replace the limit switch as an assembly. Disassembly causes a defective operation, and a
major accident may occur.
Prohibited
(To be continued)
Disassembly procedure Removing the controller cover
Danger

Other manuals for KITO ER2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KITO ER2 Series and is the answer not in the manual?

KITO ER2 Series Specifications

General IconGeneral
Control Voltage24V
Duty Cycle40% ED
Protection ClassIP55
Temperature Range-20°C to +40°C
TypeElectric Chain Hoist
Frequency50/60 Hz
Motor InsulationClass F
Brake TypeElectromagnetic
Load Chain GradeGrade 80
Ambient Temperature-20°C to +40°C
Power Supply3-phase
Lift Height3 to 30 meters
Chain Falls1 or 2
Voltage200-240V, 380-480V