43
4.9 EMERGENCY PROCEDURES
• Locate the override knob on the front of the leg lever valve and screw all the way
out.
• Remove the plasc spacer and keep this safe.
• Then screw the override knob back into the valve as far as it will go. Do not over-
ghten this.
• Whilst pumping the handpump, operate the leg controls as normal to fully retract
the outriggers.
• Once completed, remove the handpump handle and place it back in the cab. Unscrew the override valve, ret the plasc
spacer and ret the valve.