42
4.9 EMERGENCY PROCEDURES
It is the responsibility of the operator to carry out a full risk assessment before using the machine at each site in case an
emergency procedure is needed.
1) ENGINE AND/OR HYDRAULIC PUMP FAILURE
In the event of engine power failure but electrical system is working, please follow the instrucons below to operate the
emergency funcons:
• From the basket controls, press and hold the emergency motor switch on the electrical box.
• Operate the funcons as normal to bring the booms back into the stowed posion.
2) IN THE EVENT OPERATOR IS INCAPACITATED OR BASKET CONTROL PANEL FAILURE
• From the lower control staon, turn the key switch to lower controls. Press and hold the
emergency motor switch on the electrical box.
• Operate the funcons as normal to bring the booms back into the stowed posion.
• To raise the outriggers from the lower control staon, turn the key switch to outriggers.
• Press and hold the emergency motor switch on the main electrical box and raise the legs
using the 4 levers under deck.
If the electrical system has also failed, please follow the procedure as outlined below(3).
Note!! The emergency motor MUST NOT be used for more than 3 minutes without a break to prevent overheang
3) ENGINE AND/OR HYDRAULIC PUMP AND ELECTICAL FAILURE
In the event of engine and electrical power failure, please follow the instrucons set out below:
• Ensure the tap at the lower control staon is in the correct posion as per photo 1.
• Locate the emergency handpump handle in the vehicle cab. At the lower control
staon, insert the handpump handle into the handpump and screw in.
• Whilst pumping the handpump, operate the boom controls as normal to bring the
boom down safely. The booms can be fully stowed.
• Once this is completed, break the seal on the tap and move this into the other
posion as per photo 2.
2
1