A-61670 August 2014 7-7
Cleaning the imaging
guides
12. Wipe the upper and lower imaging guides with a Staticide wipe.
13. Wipe the upper and lower imaging guides again with an almost-dry
Staticide wipe to remove any streaks.
14. Close the scanner cover.
15. When finished with all cleaning procedures, turn on the scanner.
Running a transport
cleaning sheet
The transport should be cleaned with a transport cleaning sheet fed several
times.
1. Remove the wrapping from the transport cleaning sheet.
2. Adjust the input elevator and output tray side guides to the widest position.
3. Place the transport cleaning sheet in the center of the input elevator in
landscape orientation with the adhesive side up.
4. Scan the transport cleaning sheet.
5. Remove the transport cleaning sheet from the output tray and place it in
the center of the input elevator in landscape orientation with the adhesive
side down and rescan.
6. Repeat Steps 3 - 5 until the rollers are clean.
NOTE: When the transport sheet gets dirty and/or loses its tackiness, discard
it and use a new one.
Final cleaning steps When finished running the transport cleaning sheet:
1. Open the scanner cover.
2. Wipe the upper and lower imaging guides with a lint-free cloth.
3. Close the scanner cover and scan a test image to ensure image quality.