3.5.16 ICAP_YRESOLUTION
Type:
TW_UINT16
Supported Messages:
MSG_GET - TW_ENUMERATION
MSG_GETCURRENT - TW_ONEVALUE
MSG_GETDEFAULT - TW_ONEVALUE
MSG_RESET – TW_ONEVALUE
MSG_SET – TW_ONEVALUE, TW_ENUMERATION, TW_RANGE
MSG_QUERYSUPPORT - TW_ONEVALUE
Allowed Values:
100, 150, 200, 240, 300, 400, 500, 600
Default Value:
200
Query Support Value:
TWQC_GET |TWQC_GETDEFAULT |TWQC_GETCURRENT | MSG_SET| MSG_RESET
Stored in registry:
Yes
Stored in profile:
Yes
Note: ICAP_XRESOLUTION will be updated to match the current setting of
ICAP_YRESOLUTION
3.6 O
PTIONAL TWAIN OPERATIONS
Optional Operations are those operations that have been implemented to further enhance the
representation of the Supported Ngenuity Product Features.
3.6.1 DG_CONTROL / DAT_SETUPFILEXFER
Supported Messages: MSG_GET (state 4–6), MSG_GETDEFAULT (state 4–6), MSG_RESET
(state 4), and MSG_SET (state 4-6)
Default configuration of the TW_SETUPFILEXFER structure shall be:
FileName = “<temp path>\image0.bmp”
Format = TWFF_BMP
VRefNum = 0
3.6.2 DG_IMAGE / DAT_IMAGEFILEXFER
Supported Messages: MSG_GET (state 6)
MSG_GET shall cause a file to be generated in the current file format and location negotiated in
DAT_SETUPFILEXFER