To turn on this mode set to TRUE capability BBH_CAP_ENABLE_ADVANCED_FRAMES. If
this capability is TRUE, then TWAIN DS will ignore other scan modes.
Every window can be addressed using capability BBH_CAP_ADV_WND_ID. See “Capabilities
Dependencies” table for information which capabilities can be set separately for each window.
3.13 I
NSTALLER / UNINSTALLER
The basic installer is using Windows Installer (MSM) and Driver Install Frameworks (DIFX) to
update low level drivers and .inf based PNP.
Separate installers are provided for both 32 & 64-bit TDS.
64 bit installer will install both 32-bit and 64-bit TDS.
3.14 E
RROR DETECTION / RECOVERY
Device Not Present – if CAP_INDICATORS is TRUE, then user shall be presented with
appropriate message otherwise TWAIN API shall respond with
TWCC_CHECKDEVICEONLINE.
Scan errors – when CAP_INDICATORS is TRUE, user shall be presented with a message. TWAIN
API shall respond with the appropriate TWCC_error code.
3.15 L
OCALIZATION
All strings are stored in the resource file. Initial release is English only version.