Ngenuity TWAIN Data Source November 19, 2009
Page 65 of 99
MSG_GETCURRENT - TW_ONEVALUE
MSG_GETDEFAULT - TW_ONEVALUE
MSG_RESET – TW_ONEVALUE
MSG_SET – TW_ONEVALUE, TW_RANGE
MSG_QUERYSUPPORT - TW_ONEVALUE
Allowed Values:
0 to 255
Default Value:
128
Query Support Value:
TWQC_GET |TWQC_GETDEFAULT |TWQC_GETCURRENT | MSG_SET| MSG_RESET
Stored in registry:
Yes
Stored in profile:
Yes
3.8.8 BBH_CAP_ADV_WND_ENABLE
This capability specifies if the current window (specified by BBH_CAP_ADV_WND_ID) will be
read from the scanner. It can be different on deferent windows.
Type:
TW_BOOL
Supported Messages:
MSG_GET - TW_ENUMERATION (for 2.0 applications), TW_ONEVALUE (for
<2.0Applications)
MSG_GETCURRENT - TW_ONEVALUE
MSG_GETDEFAULT - TW_ONEVALUE
MSG_RESET – TW_ONEVALUE
MSG_SET – TW_ONEVALUE, TW_ENUMERATION
MSG_QUERYSUPPORT - TW_ONEVALUE
Allowed Values:
FALSE, TRUE
Default Value:
FALSE
Query Support Value:
TWQC_GET |TWQC_GETDEFAULT |TWQC_GETCURRENT | MSG_SET| MSG_RESET
Stored in registry:
No (Non standard TWAIN mechanism)
Stored in profile:
Yes