Ngenuity TWAIN Data Source November 19, 2009
Page 40 of 99
MSG_GETDEFAULT - TW_ONEVALUE
MSG_RESET – Not supported
MSG_SET – Not supported
MSG_QUERYSUPPORT - TW_ONEVALUE
Allowed Values:
TRUE, FALSE
Default Value:
TRUE, FALSE
Query Support Value:
TWQC_GET |TWQC_GETDEFAULT |TWQC_GETCURRENT
Stored in registry:
No (Read Only capability)
Stored in profile:
No (Read Only capability)
Note: Use Read/ScannerStatus with ReadScanner bit set to 1 to force scanner update the status.
3.7.10 CAP_FEEDERENABLED
Type:
TW_BOOL
Supported Messages:
MSG_GET - TW_ENUMERATION (for 2.0 applications), TW_ONEVALUE (for
<2.0Applications)
MSG_GETCURRENT - TW_ONEVALUE
MSG_GETDEFAULT - TW_ONEVALUE
MSG_RESET – Not supported
MSG_SET – Not supported
MSG_QUERYSUPPORT - TW_ONEVALUE
Allowed Values:
TRUE
Default Value:
TRUE
Query Support Value:
TWQC_GET |TWQC_GETDEFAULT |TWQC_GETCURRENT
Stored in registry:
No (Only one supported value)
Stored in profile:
No (Only one supported value)