EasyManuals Logo

Komatsu Galeo PC800-8 User Manual

Komatsu Galeo PC800-8
1117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #743 background imageLoading...
Page #743 background image
PC800, 850-8 17
40 Troubleshooting SEN00793-02
E-4 Auto-decelerator does not operate
Failure
phenomenon
The auto-decelerator does not operate.
Relative
information
Since the auto-decelerator is set to 1,400 rpm, it does not operate if the fuel control dial is not set above
this level.
Check the display on the monitor panel while the engine is running.
If the display on the monitor panel is abnormal, carry out troubleshooting in “*** is not displayed normally
in monitoring function”.
Possible causes
and standard
value in normal
state
Cause Standard value in normalcy and references for troubleshooting
1
Defective boom RAISE signal
Monitoring code Item Normal display
01900
Pressure switch 1
Boom RAISE
Lever operated: ON
Lever in neutral: OFF
2
Defective boom LOWER
signal
Monitoring code Item Normal display
01900
Pressure switch 1
Boom LOWER
Lever operated: ON
Lever in neutral: OFF
3 Defective arm IN signal
Monitoring code Item Normal display
01900
Pressure switch 1
Arm IN
Lever operated: ON
Lever in neutral: OFF
4 Defective arm OUT signal
Monitoring code Item Normal display
01900
Pressure switch 1
Arm OUT
Lever operated: ON
Lever in neutral: OFF
5
Defective bucket CURL
signal
Monitoring code Item Normal display
01901
Pressure switch 2
Bucket CURL
Lever operated: ON
Lever in neutral: OFF
6
Defective bucket DUMP
signal
Monitoring code Item Normal display
01901
Pressure switch 2
Bucket DUMP
Lever operated: ON
Lever in neutral: OFF
7 Defective swing signal
Monitoring code Item Normal display
01900
Pressure switch 1
Swing
Lever operated: ON
Lever in neutral: OFF
8 Defective left travel signal
Monitoring code Item Normal display
01901
Pressure switch 2
Left travel
Lever operated: ON
Lever in neutral: OFF
9 Defective right travel signal
Monitoring code Item Normal display
01900
Pressure switch 1
Right travel
Lever operated: ON
Lever in neutral: OFF
10 Defective service signal
Monitoring code Item Normal display
01901
Pressure switch 2
Service
Lever operated: ON
Lever in neutral: OFF
11 Defective pump controller
If causes 1 – 10 are not detected, the pump controller may be defective.
(Since trouble is in the pump controller, troubleshooting cannot be carried out.)
12 Defective engine controller
If causes 1 – 10 are not detected, the engine controller may be defec-
tive.
(Since trouble is in the pump controller, troubleshooting cannot be carried out.)