20
426351/A
Connectingthetranspondertoexternal
powerandrespondersignals
Thefollowinginformationwillhelpwithconnectingtheexternalpowertothe
transponder.
Procedure
1Usethespeciedpigtail.
2Connectwire6and8inthepigtail(theON/OFFfunction).
3Ensurethattheexternalpowersupply24Vdcisbetween18and36Vdc.
4Checktherespondertriggersignal.
5SwitchONtheunitbyinsertingtheexternalpower/respondercable.
Iftheresponderfunctionistobeused,theunitcanbecheckedinairondeck,using
aTTC30(TransponderTestandConguration)unit.
Furtherrequirements
Predeploymentchecksmustbeperformedbeforetheunitisinstalled/used.
ConnectingthecNODEMicrototheROV
ItisveryimportanttoreadtheproceduresbeforeconnectingthecNODEMicrotothe
ROV .
Prerequisites
Note
AlwaysconnectthecNODEMicrototheROVbeforeturningonthepowersupply(24
VDC).
cNODEMicroInstructionManual