22
426351/A
Context
TosetTTCPOWERuseleft/rightarrowstochoosepowerlevelandtapSETtoconrm
yourselection.
Procedure
1Connectthetesttransducercabletotheupperrightconnector.
2PlacetheTesttransducerfacetofacewiththetransponder.
3CommunicationbetweentheTTCandthetranspondermayeasilybetestedby
selectingtheACOUSTICTESTtab.
4Enterserialnumber.
5Enterthetransponderchannelnumber.
6TapINTERROGATE.
7Agreenindicatorwillblinkonthedisplayifthereisacousticcontactwiththe
transponder.
8TapINTERROGATEagaintostoptheACOUSTICTEST.
Conguringthetransponder
Thiswillleaveyourtransponderwithanewconguration.
Prerequisites
ThetranspondermustbeconnectedtotheTransponderTestandCongurationunit
viaaTTCTestandcongurationcable.
Procedure
1TapTransponderConguration.
2Makechangestothecongurationintherelevantelds.
3TapDOWNLOADANEWCONFIGURATIONtoupdatethetransponder.
Result
Ifthecongurationissuccessfulyouwillreceiveamessage;Downloadednew
congurationsucceededandresetperformedsucessfully.
Ifthecongurationisnotsuccessfulyouwillreceiveawarningmessage;Download
congfailed.Checkallcablesandtryagain.
Furtherrequirements
SeetheInstructionmanualfortheTransducerTestandCongurationunit,document
number350839,formoreinformation.