426351/A
33
2DisconnectthecNODEMicrofromthecNODE
batterycharger.
LEDindicatorstatusandtroubleshooting
LEDindicatorWhatitmeansHowtoxthis
FlashinggreenThebatteryischarging
Constantgreen
Thebatteryisfully
charged
FlashingredThefollowingmight
haveoccurred:
•thechargerisnot
connectedtothe
transponder
•failurein
charger/transponder
connection
•chargermightbe
faulty
Dothefollowing:
•disconnectallcablesandwait1minutebefore
reconnectingthecablesandconnectpowersupplyto
mains(110or220V ac).
IftheLEDindicatorisstillashingredthenthe
followingmighthaveoccurred:
•thechargermightbefaulty.Contactyourlocal
KongsbergMaritimeofceifthisisthecase.
ConstantredThefollowingmight
haveoccurred:
•thebattery
temperaturemightbe
outsidethecharging
specication
•possiblebatteryfailure
Dothefollowing:
•thebatterytemperatureisoutsidethespecication
andneedstoclimatisebeforecharging.(10to40°C)
•disconnectallcablesandwait1minutebefore
reconnectingthecablesandconnectpowersupplyto
mains(110or220V ac).
IftheLEDindicatorisstillredthenthefollowingmight
haveoccurred:
Maintenance