2DisconnectthecNODEMicrofromthecNODE
batterycharger.
LEDindicatorstatusandtroubleshooting
LEDindicatorWhatitmeansHowtoxthis
FlashinggreenThebatteryischarging
Constantgreen
Thebatteryisfully
charged
FlashingredThefollowingmight
haveoccurred:
thechargerisnot
connectedtothe
transponder
failurein
charger/transponder
connection
chargermightbe
faulty
Dothefollowing:
disconnectallcablesandwait1minutebefore
reconnectingthecablesandconnectpowersupplyto
mains(110or220V ac).
IftheLEDindicatorisstillashingredthenthe
followingmighthaveoccurred:
thechargermightbefaulty.Contactyourlocal
KongsbergMaritimeofceifthisisthecase.
ConstantredThefollowingmight
haveoccurred:
thebattery
temperaturemightbe
outsidethecharging
specication
possiblebatteryfailure
Dothefollowing:
thebatterytemperatureisoutsidethespecication
andneedstoclimatisebeforecharging.(10to40°C)
disconnectallcablesandwait1minutebefore
reconnectingthecablesandconnectpowersupplyto
mains(110or220V ac).
IftheLEDindicatorisstillredthenthefollowingmight
haveoccurred:
Maintenance