2.4 Changing Operation Panel Installation Position
2-21
17 Install the first front back panel.
Seven screws (M4 × 8)
Hold the bottom of the first front back panel with both
hands and push the top of the panel into the top panel.
18 Install the second front back panel.
Six screws (M4 × 8)
Four spacers
This is the final step in the process of changing the installation position of the operation panel.
Proceed to “2.5 Moving to and Fixing at Installation Location to move the machine and fix it at the
installation location