Saving and loading data
En-26
9. Use“.KSCAllocation”tospecifyhowthesample
datawillbeloaded,andwhetherornotexisting
sampledatawillbeerased.
Appendwillleaveallcurrently‐loadedSampling
Mode,UserSampleBank,and/orEXsdataintact.
SamplingModeMultisamplesandSampleswillbe
loadedintothenextavailablevacantnumbers
followingtheexist
ingdata.
ClearSamplingModeDatawilleraseall
MultisamplesandSamplesfromSamplingMode,and
loadthedatainthesameconfigurationwithwhichit
wassaved.ExistingEXsandUserSampleBankdatais
leftintact.
ClearAllissimilartoClearSamplingModeData,
above,butalsoun‐lo
adsexis
tingEXsandUserSample
Bankdatabeforeloadingthenew.KSCfile.Thisfrees
upthemostmemoryforthenew.KSC.
Youcanusetheinformationatthebottomofthedialog
box,includingMemoryRequired,(Memory)
Available,andEnoughslotsforSamples&MS,to
de
termine
whetherornotyouneedtofreeuproomfor
thenew.KSC.
10.SettheLoadMethodasdesired.
ThissetsthepreferredwaytoloadtheEXsandUser
SampleBankdataintheKSC:loadthemintoRAM,
useVirtualMemory,orusethesettingstoredinthe
KSC.IftheKSChasnoEXsorUs
erSampleBankdat
a,
thiswillbegrayedout.
11.PresstheOKbuttontoloadthedata.
NeverdisconnectUSBdevicesorremovedata‐
storagemediawhileloadingorsaving.
WhenloadingPrograms,Combinations,Songs,Set
Lists,DrumKits,WaveSequences,orKARMAUser
GE
s,makesu
rethattheGlobalBasicSetuppage’s
MemoryProtectsettingsareturnedoff(unchecked).
Iftheyareon,youwon’tbeabletoloadthedata.
Loading individual banks from a .PCG file
1. GototheLoadpage.
2. Selectthe.PCGfilecontainingthedatayouwant
toload.
3. PresstheLoadbutton.
4. Setthe.PCGContentstoloadthedesired
individualbanks.
5. Selectthebanktoloadintoviathe“To”parameter.
Automatic reference correction
Ifyouset.PCGContentsandTotodifferentbanks,
anyreferencesinthedatawillbeupdatedtomatchthe
newbank.Forinstance,let’ssaythatyou’reloading
fromthePCG’sBankI‐AintoBankU‐G.IfthePCG’s
CombinationsusedProgramsfromBankI‐A,theywill
beupd
atedtotheus
ethePrograms’newlocationsin
BankU‐G.ThesameistrueforanyDrumKitsorWave
SequencesusedbyPrograms.
Ifyou’reloadingsequencerdataatthesametime(with
Load.SNGtoochecked),anyProgramandBank
ChangemessageswithintheSongswillalsobe
corrected.
Loading multiple files at once
Youcanselecttwoormorefilesatonce,andloadthem
inasingleoperation.Todoso:
1. PresstheMultipleSelectcheck‐boxatthebottom
ofthescreen,sothatit’senabled.
Thiscanbehandyforloadingmultiplesamplefilesat
once,importingbanksofDXsounds,andsoon.
MultipleSe
lectworksforotherdiskoperationsas
well,includingDelete(sobecareful!).
NotethatwhenMultipleSelectison,youcan’tchange
toadifferentdirectory.Whenyou’redone,turnitoff
again.
Youcanalsouse“wildcards”toselectmultiplefiles.
Formoreinformation,see“Loadingmu
ltip
lefilesat
once”underthe“Loadselected”menucommandin
thePG’sDiskchapter.