Kramer Electronics Ltd.
SL-280 – Protocol 3000
51
GPIO-VOLT
Functions
Permission
Transparency
Set:
-
-
-
Get:
GPIO-VOLT?
End User
Public
Description
Syntax
Set:
Get:
Get active voltage
levels of HW GPIO
#GPIO-VOLT?␠HwGpioNumber␍
Response
~nn
@GPIO-VOLT␠
HwGpioNumber,Voltage
␍␊
Parameters
HwGpioNum
– hardware GPIO number: 1–8
Voltage – voltage
0
to
30000
millivolts
Response Triggers
Notes
This command is not available in digital out mode
Example
Get HW GPIO #1 active voltage level:
#GPIO-VOLT?
1<CR>
IR-LEARN
Functions
Permission
Transparency
Set:
IR-LEARN
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Send IR learning
command
#IR-LEARN␠CommandName,Timeout␍
Get:
-
-
Response
~nn@IR-LEARN␠
CommandName,IR_Status
␍␊
Parameters
CommandName – String: IR command name limited to 15 chars (white space or commas not allowed).
Timeout – Timeout in seconds: 1–60
IR_Status – 0 (Sent), 1 (Stop), 2 (Done), 3 (Busy), 4 (Wrong Parameter), 5 (Nothing to Stop), 6 (Start), 7
(Timeout),
8
(Error)
Response Triggers
Notes
Example
Send IR learning command PowerToggle, with a 30 second timeout:
#IR-LEARN
PowerToggle,30<CR>