EasyManua.ls Logo

Kramer SL-280 - Page 55

Kramer SL-280
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kramer Electronics Ltd.
SL-280Protocol 3000
53
IR-STOP
Functions
Permission
Transparency
Set:
IR-STOP
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Send IR stop
command to port
#
IR-STOP
PortNum,Cmd_id,CmdName
Get:
-
-
Response
~nn
@IR-STOP
PortNum,Cmd_id,CmdName,Status
␍␊
Parameters
PortNum
IR port transmitting the command:
1
8
, * (broadcast to all ports)
Cmd_idcommand ID, numeric string of up to 9 digits for flow control and response commands from
device
CmdNamecommand name, string of up to 15 alpha-numeric characters
Status
0
(no error)
Response Triggers
Notes
Example
Send IR stop command for IR port number 1, for PowerTog command with ID of 25:
#IR-STOP 1,25,PowerTog<CR>
RELAY-STATE
Functions
Permission
Transparency
Set:
RELAY-STATE
End User
Public
Get:
RELAY-STATE?
End User
Public
Description
Syntax
Set: Set relay state
#RELAY-STATE
RelayNumber,RelayState
Get: Get relay state
#RELAY-STATE?
RelayNumber
Response
~nn
@RELAY-STATE
RelayNum,RelayState
␍␊
Parameters
RelayNumberRelay port number: 18
RelayState relay state:
0
(open),
1
(closed), see note
Response Triggers
Notes
When relays 1 and 5 are connected as NC (Normally Closed) (see Connecting the Relay Ports on page 8),
the RelayState parameter is reversed:
0
(closed),
1
(open).
Example
Set Relay port number 2 state to closed:
#RELAY-STATE
2,1<CR>

Other manuals for Kramer SL-280

Related product manuals