TP-578H - Protocol 3000
25
25
Command - HDCP-STAT
Command Type - System
Command Name
Permission
Transparency
Set:
-
-
-
Get:
HDCP-STAT?
End User
Public
Description
Syntax
Set:
None
-
Get:
Get HDCP signal status
#HDCP-STAT? stage,stage_id
Response
Set / Get: ~ nn@HDCP-STAT stage,stage_id,mode␍␊
Parameters
stage input/output
stage_id - number of chosen stage (1.. max number of inputs/outputs)
actual_status - signal encryption status - valid values ON/OFF
Response Triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
Response is sent to all com ports after execution if HDCP-STAT was set by any other external control
device (button press, device menu and similar) or HDCP mode changed
Notes
Command - HELP
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
-
-
-
Get:
HELP
End User
Public
Description
Syntax
Set:
-
-
Get:
Get command list or help for specific
command
2 options:
1. #HELP
2. #HELPcommand_name
Response
1. Multi-line: ~nn@Device available protocol 3000 commands:␍␊command,command…␍␊
To get help for command use: HELP (COMMAND_NAME)␍␊
2. Multi-line: ~nn@HELPcommand: ␍␊description␍␊ USAGE:usage ␍␊
Parameters
Response Triggers
Notes