TP-590Rxr - Protocol 3000
49
10.2.1.16 LDFW
Command - LDFW
System - Packets
Command Name
Permission
Transparency
Set:
LDFW
Internal SW
Public
Get:
-
-
-
Description
Syntax
Set:
Load new firmware file
Step 1: #LDFWsize
Step 2: If ready was received, send
FIRMWARE_DATA
Get:
-
-
Response
Response 1: ~nn@LDFWsizeREADY␍␊ or ~nn@LDFWERRnn␍␊
Response 2: ~nn@LDFWsizeOK␍␊
Parameters
size - size of firmware data that is sent
FIRMWARE_DATA - HEX or KFW file in protocol packets
Response Triggers
Notes
In most devices firmware data is saved to flash memory, but the memory does not update until
receiving the UPGRADE” command and is restarted. Use this command in dedicated SW application