TECHNICAL DATA 6
27
OPTIMASS 3000
www.krohne.com10/2015 - 4001593002 - MA OPTIMASS 3000 R02 en
6.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Downloadcenter).
Measuring system
Measuring principle Coriolis mass flow
Application range Mass flow and density measurement of fluids, gases
Measured values Mass, density, temperature
Calculated values Volume, referred density, concentration, velocity
Design
Basic System consists of a measuring sensor and a converter to process the
output signal
Features Fully welded maintenance free sensor with single Z-shaped measuring tube
Variants
VariantsVariants
Variants
Compact version Integral converter
Remote version Available with field, wall or 19¨ rack mount versions of the converter
Modbus version Sensor with integral electronics providing Modbus output for connection to a
PLC
Measuring accuracy
Mass
MassMass
Mass
Liquid ±0.1% of actual measured flow rate + zero stability
Gas ±0.5% of actual measured flow rate + zero stability
Repeatability Better than 0.05% plus zero stability (includes the combined effects of
repeatability, linearity and hysteresis)
Zero stability
Zero stabilityZero stability
Zero stability
Stainless Steel / Hastelloy® 0.0057% of maximum flow rate with respective sensor size
Reference conditions
Reference conditionsReference conditions
Reference conditions
Product Water
Temperature +20°C / +68°F
Operating pressure 1 barg / 14.5 psig
Effect on sensor zero point caused by a shift in process temperature
Effect on sensor zero point caused by a shift in process temperatureEffect on sensor zero point caused by a shift in process temperature
Effect on sensor zero point caused by a shift in process temperature
Stainless Steel / Hastelloy® 0.0056% per 1°C / 0.0031% per 1°F
Effect on sensor zero point caused by a shift in process pressure
Effect on sensor zero point caused by a shift in process pressureEffect on sensor zero point caused by a shift in process pressure
Effect on sensor zero point caused by a shift in process pressure
Stainless Steel / Hastelloy® 0.013% of the max flow rate per 1 barg / 0.0009% of the max flow rate per 1
psig
Density
DensityDensity
Density
Measuring range
400...3000 kg/m
3
/ 25...187 lbs/ft
3
Accuracy
±2 kg/m
3
/ ±0.13 lbs/ft
3
On site calibration
±0.5 kg/m
3
/ ±0.033 lbs/ft
3
MA_OPTIMASS_3000_en_151014_4001593002_R02.book Page 27 Wednesday, October 14, 2015 1:20 PM