5.4.3 Electrical connection
5.4.3.1 Removing the housing cover
DANGER
Contact with live components
Risk of fatal injury due to electric shock!
Never remove the upper housing part from the heat sink.
Mind the capacitor discharge time.
After switching off PumpDrive, wait five minutes until dangerous voltages have
discharged.
The housing cover comprises a V-shaped cover for the power and motor connection
cable connections and an L-shaped cover for the control cable connection.
1. Remove the cross recessed head screws on the C-shaped cover.
2.
Remove the L-shaped cover.
1. Remove the cross recessed head screws on the V-shaped cover.
2.
Remove the V-shaped cover.
1. Remove the cross recessed head screws on the control panel or blanking plate.
2.
Remove the control panel or blanking plate.
L-shaped cover
V-shaped cover
Control panel/blanking
plate
5 Installation at Site
PumpDrive
25 of 162