Symptom Probable Cause Solution
Reference
Page
All Electrical
Equipments Do Not
Operate
Battery discharged or defective Recharge or replace G-24,
1-S19
Battery positive cable disconnected or
improperly connected
Repair or replace –
Battery negative cable disconnected or
improperly connected
Repair or replace –
Slow blow fuse blown (40 A) Replace G-35
Fuse Blown
Frequently
Short-circuited Repair or replace –
Battery Discharges
Too Quickly
Battery defective Replace 1-S19
Dynamo defective Repair or replace 6-S21
Regulator defective Replace 6-S15, 16
Wiring harness disconnected or improperly
connected (between battery positive terminal
and regulator B terminal)
Repair or replace –
Cooling fan belt slipping Adjust tension G-28