EasyManua.ls Logo

Kubota GR1600EC2 - Check Points of Every 2 Years

Kubota GR1600EC2
241 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G-34
GR1600EC2, WSM
G GENERAL
Flushing Cooling System and Changing Coolant (Continued)
IMPORTANT
When the anti-freeze is mixed with water, the anti-freeze
mixing ratio must be less than 50%.
*At 0.1013 MPa (760 mmHg) pressure (atmospheric). A higher
boiling point is obtained by using a radiator pressure cap which
permits the development of pressure within the cooling system.
1. Adding the LLC
(1) Add only water if the mixture reduces in amount by
evaporation.
(2) If there is a mixture leak, add the LLC the same manufacture
and type in the same mixture percentage.
*Never add any long-life coolant of different manufacture.
(Different brands may have different additive components, and
the engine may fail to perform as specified.)
2. When the LLC is mixed, do not employ any radiator cleaning
agent. The LLC contains anti-corrosive agent. If mixed with the
cleaning agent, sludge may build up, adversely affecting the
engine parts.
3. Kubota's genuine long-life coolant has a service life of 2 years.
Be sure to change the coolant every 2 years.
NOTE
The above data represent industry standards that
necessitate a minimum glycol content in the concentrated
anti-freeze.
When the coolant level drops due to evaporation, add water
only to keep the anti-freeze mixing ratio less than 50%. In
case of leakage, add anti-freeze and water in the specified
mixing ratio before filling in to the radiator.
W1068193
[9] CHECK POINTS OF EVERY 2 YEARS
Replacing Fuel Lines
1. Replace the fuel line.
Refer to "Checking Fuel Lines and Fuel Filter". (See page G-27.)
W1019995
Replacing Radiator Hose
1. Replace hoses and clap bands every 2 years or earlier if checked
and found that hoses are swollen, hardened or cracked.
W1070217
Replacing Intake Air Line
1. Replace the intake air line.
Refer to "Checking Intake Air Line". (See page G-31.)
W1056499
Replacing Mower Gear Box Oil Seals
1. Replace the mower gear box oil seals.
Refer to "Disassembling Gear Box". (See page 7-S9.).
W1070302
Vol %
Anti-freeze
Freezing Point Boiling Point*
°C (°F) °C (°F)
40 -24 (-12) 106 (222)
50 -37 (-34) 108 (226)
KiSC issued 07, 2006 A

Table of Contents