ENGINE
(5) Electrical System
CAUTION
To avoid accidental short circuit, be sure to attach the positive cable to the positive terminal before the
negative cable is attached to the negative terminal.
Never remove the battery cap while the engine is operating.
Keep electrolyte away from eyes, hands and clothes. If you are spattered with it, wash it away completely
with water immediately.
Keep open sparks and flames away from the battery at all times. Hydrogen gas mixed with oxygen
becomes very explosive.
IMPORTANT
If the machine is to be operated for a short time without battery (using a slave battery for starting), use
additional current (lights) while engine is operating and insulate terminal of battery. If this advice is
disregarded, damage to alternator and regulator may result.
Battery Voltage
1. Stop the engine.
2. Measure the voltage with a circuit tester between the battery
terminals.
3. If the battery voltage is less than the factory specification, check
the battery specific gravity and recharge the battery.
W10125620
Battery voltage Factory spec. More than 12 V
(1) Positive Terminal (2) Negative Terminal
KiSC issued 06, 2020 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota WSM 07-E3B Series and is the answer not in the manual?

Kubota WSM 07-E3B Series Specifications

General IconGeneral
BrandKubota
ModelWSM 07-E3B Series
CategoryEngine
LanguageEnglish

Related product manuals