The standard Commander is rated at 8 CFM. Check the spec plate if the optional H-1000 or 555 was
ordered with your Commander. Air should be supplied inside the left rear leg to the Filter/ Regulator /
Lubricator module. Once the machine is up and running, sight through the glass on top of the
lubricator, and turn the adjustment screw so one drop every two cycles is fed to the system. Check the
filter bow daily and empty if its more than half full of water.
Finally, if your plant is located in a humid area we recommend a air dryer on your compressed air