58
FERROUS PROXIMITY EYE THAT CONTROLS THE ROUTER CARRIAGES
MOVEMENT DOWN AND TO THE RIGHT IS OUT OF ADJUSTMENT:
1. Make sure that the ferrous proximity switch is clean and close enough to read
the metal flag that it is looking for in order to initiate the next phase of its cycle
of operation.
ONE OR MORE THROUGH BEAMS ARE BAD:
1. When the front section is down and out of the way, the through beams should
light up to indicate that they are operating. If they don’t light up replace.
ENVIRONMENT TOO COLD:
1. The lubrication required for smooth movement of all assemblies must be
sufficiently warm to afford any of its viscous qualities. If it is very cold in your
shop it will prevent smooth movement of the front section (as well as other
assemblies). Let the machine dry cycle for a while to see if range and
smoothness of motion returns. If the warm up time helps the problem put a
heater near the machine to keep the oil from coagulating.