12. COOLING SYSTEM
12-15
MXU 300/250
THERMOSTAT INSPECTION
Suspend the thermostat in a pan of water
over a burner and gradually raise the water
temperature to check its operation.
Technical Data
Begins to open 80±2
Full-open 90
Valve lift 3.54.5 mm
THERMOSTAT INSTALLATION
The installation sequence is the reverse of
removal.
Fill the cooling system with the specified
coolant. (
page
12-7)
O-ring
Thermosenso
r
Thermosta
t
Thermomete
r
Do not let the thermostat touch the pan
as it will give a false reading.
Replace the thermostat if the valve
stays open at room temperature.
Test the thermostat after it is opened for
about 5 minutes and holds the
temperature at 70.
Replace the O-ring with a new one and
apply grease to it.