17. IGNITION SYSTEM
17-2
MXU 300/250
IGNITION CIRCUIT (OFF ROAD)
SERVICE INFORMATION
GENERAL INSTRUCTIONS
Check the ignition system according to the sequence specified in the Troubleshooting.
The ignition system adopts ignition unit, change gear control and the ignition timing cannot be
adjusted.
If the timing is incorrect, inspect the ignition unit, A.C. generator, change gear control and
replace any faulty parts. Inspect the ignition unit with a ignition unit tester
Loose connector and poor wire connection are the main causes of faulty ignition system. Check
each connector before operation.
Use of spark plug with improper heat range is the main cause of poor engine performance.
The inspections in this section are focused on maximum voltage. The inspection of ignition coil
resistance is also described in this section.
Inspect the spark plug referring to chapter 3.