2LK/2LN/2LM/2LC-2
1-3-36
U034 5. Change the setting value using the cursor +/- or numeric keys.
For output example 1, increase the value. For output example 2, decrease the value.
Figure 1-3-4
6. Press the start key. The value is set.
Remark
When changing the setting value of [Large] each item is modified, equal to amount of the value
which is changed adds also the value of [Small] each item and is pulled.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
Adjustment: Center line adjustment
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
*: 45 ppm/55 ppm model only.
Item No. Description
Correct image
Output
example 1
Output
example 2
Leading edge
registration
(20 ± 1.0 mm)
U034
U066
(P.1-3-54)
U071
(P.1-3-59)
Display Description
Setting
range
Initial
setting
Change in
value per step
MPT Paper feed from MP tray -3.0 to 3.0 0 0.1 mm
Cassette1 Paper feed from cassette 1 -3.0 to 3.0 0 0.1 mm
Cassette2 Paper feed from cassette 2 -3.0 to 3.0 0 0.1 mm
Cassette3 Paper feed from optional cassette 3 -3.0 to 3.0 0 0.1 mm
Cassette4 Paper feed from optional cassette 4 -3.0 to 3.0 0 0.1 mm
Cassette5 Paper feed from optional cassette 5 -3.0 to 3.0 0 0.1 mm
Cassette6 Paper feed from optional cassette 6* -3.0 to 3.0 0 0.1 mm
Cassette7 Paper feed from optional cassette 7* -3.0 to 3.0 0 0.1 mm
Duplex Duplex mode (second) -3.0 to 3.0 0 0.1 mm