2LK/2LN/2LM/2LC-2
1-3-116
U224 Panel sheet extension
Description
Changes the image data and the message of the opening screen at the machine startup and the
image data and the message of the service call screen to user specified data.
Purpose
Set according to the preference of the user.
Setting
1. Write the image data or the message data to the USB memory.
2. Insert USB memory in USB memory slot of the machine.
3. Turn the main power switch on.
4. Enter the maintenance item.
5. Press the start key.
6. Select the [Install] or [UnInstall].
7. Select the item.
8. Press the start key. Installation or uninstallation is started.
9. When normally completed, [OK] is displayed.
Supplement
Displaying start display
The pre-installed graphics file is displayed at power on or recovering from sleeping.
Graphics display on service call display
The pre-installed graphics file is displayed at a service call.
How to change the message
Entering #562 (4 letters) using the numeric keypad during a service call display will let service
call messages 1 and 2.
How to reset the message display
Reverting the maintenance mode will automatically reset the message to the previous.
Caution
The graphics file for start display must be opaque. (To avoid the background from overlapping at
recovering from sleeping.)
The total size of the files installable is approximately 1.8 MB.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Install Installs the image data or the message data
UnInstall Restores the original image data or message data
Display Description Display area
Opening Img Startup screen Entire start display
Call Img Service call screen Graphic display area
Call Msg Top Service call message 1 Message display area (top)
Call Msg Detail Service call message 2 Message display area (descriptive area)