2LK/2LN/2LM/2LC
1-3-158
U411 To manually enter the target value
1. Set a specified original (P/N: 7505000005) on the platen.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [Auto] and press the start key.
5. Select [Table (Chart1)].
6. Select the item.
7. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
Method: [DP FaceUp (Chart1)]
To manually enter the target value
1. Enter the target values which are shown on the specified original (P/N: 7505000005) execut-
ing maintenance item U425. Set a specified original (P/N: 7505000005) on the DP face up.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [U425] and press the start key.
5. Select [DP FaceUp (Chart1)].
6. Select [Input].
To manually enter the target value
1. Set a specified original (P/N: 7505000005) on the DP face up.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [Auto] and press the start key.
5. Select [DP FaceUp (Chart1)].
6. Select [Input].
Item No. Description
Display Description
All Executing the all scanner adjustment
LED/AGC Executing the adjustment for LED light quantity/AGC
White Executing the white reference compensation coefficient
Input Executing the adjustment for magnification, leading edge tim-
ing and center line
C.A. Executing the adjustment for chromatic aberration filter
MTF Executing the adjustment for MTF filter
Gamma Executing the adjustment for input gamma
Matrix Executing the adjustment for matrix
Display Description
Input Executing the adjustment in the DP scanning section (first
side) for magnification, leading edge timing and center line