2LK/2LN/2LM/2LC-2
1-3-178
U464 Setting: [Print Rate(B/W)]
1. Change the setting value using the +/- keys or numeric keys.
2. Press the start key. The value is set.
Method: [Calib]
1. Select [Execute].
2. Press the start key. Calibration is executed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U465 Data reference for ID correction
Description
References the data related to ID correction.
Purpose
To check the corresponding data.
Method
1. Press the start key.
2. Select the item to be reference.
Displaying: [TCOUNT]
1. Select [TCOUNT]. The current value is displayed.
Item No. Description
Display Description
Setting
range
Initial
setting
Threshold Proportion of black/white printing 0 to 100 (%) 50
Display Description
TCONT Developer bias control value after ID correction
Laser Power Scaling factor to the value determined in light amount calibration
Bias Calib Sensor value for toner thick layer calibration
T7 CTD T7 control value
Display Description
Before(C) Developer bias control value for cyan before ID correction
Before(M) Developer bias control value for magenta before ID correction
Before(Y) Developer bias control value for yellow before ID correction
Before(K) Developer bias control value for black before ID correction
After(C) Developer bias control value for cyan after ID correction
After(M) Developer bias control value for magenta after ID correction
After(Y) Developer bias control value for yellow after ID correction
After(K) Developer bias control value for black after ID correction