EasyManua.ls Logo

Kyocera TASKalfa 3050ci - Page 627

Kyocera TASKalfa 3050ci
936 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2LK/2LN/2LM/2LC-2
2-3-77
YC1
35 PICK_SOL1_RET I 0/24 V DC PUSOL1: On/Off (RET)
Connected to
engine PWB
36 PICK_SOL1_REM I 0/24 V DC PUSOL1: On/Off (ACT)
37 CAS2_P0 O 0/3.3 V DC FS2: On/Off
38 CAS2_LIFT_UP O 0/3.3 V DC LS2: On/Off
39 CAS2_EMPTY O 0/3.3 V DC PS2: On/Off
40 PICK_SOL2_RET I 0/24 V DC PUSOL2: On/Off (RET)
41 PICK_SOL2_REM I 0/24 V DC PUSOL2: On/Off (ACT)
42 GND - - Ground
43 REG_SENS O 0/3.3 V DC RS: On/Off
44 FEED1_SENS O 0/3.3 V DC PCS: On/Off
45 BEND_SENS O 0/3.3 V DC RDS: On/Off
46 MID_MOT_PH I 0/3.3 V DC MM control signal
47 MID_MOT_REM(
ROL_CL)
I 0/3.3 V DC MM/MCL: On/Off
48 MID_MOT_CLK I 0/3.3 V DC (pulse) MM clock signal
49 MID_MOT_PD I 0/3.3 V DC MM control signal
50 ASIST_CL1 I 0/24 V DC ASCL1: On/Off
YC2
1FEED_MOT_GAI
N
- - Not used
Connected to
paper feed
motor
2 FEED_MOT_DIR O 0/3.3 V DC PFM drive switch signal
3 FEED_MOT_RDY I 0/3.3 V DC PFM ready signal
4 FEED_MOT_CLK O 0/3.3 V DC (pulse) PFM clock signal
5 FEED_MOT_REM O 0/24 V DC PFM: On/Off
6 GND - - Ground
7 24V2 O 24 V DC 24 V DC power to PFM
YC3
1 CAS1_LNG1 I 0/3.3 V DC PLSW1: On/Off
Connected to
paper length
switch 1/2,
paper width
switch 1/2, lift
motor 1/2,
paper gauge
sensor 1(U)/
(L) and paper
gauge sen-
sor 2(U)/(L)
2 CAS1_LNG2 I 0/3.3 V DC PLSW1: On/Off
3 GND - - Ground
4 CAS1_LNG3 I 0/3.3 V DC PLSW1: On/Off
5 CAS1_WID I 0/3.3 V DC PWSW1: On/Off
6 GND - - Ground
7 CAS2_LNG1 I 0/3.3 V DC PLSW2: On/Off
8 CAS2_LNG2 I 0/3.3 V DC PLSW2: On/Off
9 GND - - Ground
10 CAS2_LNG3 I 0/3.3 V DC PLSW2: On/Off
11 CAS2_WID I 0/3.3 V DC PWSW2: On/Off
12 GND - - Ground
Connector Pin Signal I/O Voltage Description

Table of Contents