80
Venom and Side Winder Toy Hauler units has furnace located in
front baggage compartment. Each furnace has it’s own owners
manual pertaining to that model. Refer to it for complete information.
Operating Instructions
1. Before operating your furnace, it is suggested to open entrance
door and windows to air out camper for any unusual odors such
as propane or other.
2. Be sure propane container has fuel and valve is open.
3. Release thermostat from “OFF” position and onto “HEAT”
position.
4. Set temperature 5 to 8 degrees above room temperature.
5. Blower will start in 0 to 15 seconds, run for 30 seconds during
heat chamber for ‘PURGE’ cycle to remove propane vapor if any.
6. Second cycle, blower continues to run, module board will; (a)
Send spark to burner tube, (b) Open valve in control to release
propane to the burner tube.
7. Ignition attempt will be made for 7 seconds.
8. Failing to ignite, board will make 2 more attempts to light the
furnace and go into lock out.
9. If after 3 attempts with no ignition, drop thermostat to lowest
setting, wait 1 minute and repeat steps 4 to 7.
10. After burner lights, set thermostat to desired setting.
11. To shut burner down, move thermostat to lowest setting or “OFF”.
12. Blower will continue to run for about 2 minutes until hot air is
removed from chamber.
To Turn Appliance Off
1. Turn Thermostat down as listed above in 11 and 12.
2. Turn off all electrical power to the appliance if service is to be
performed
3, ALL furnaces have a 12 volt DC switch built on the furnace and
must be turned ON before furnace will operate. Some models
may have a panel covering switch, making it difficult to have
access to it.
Do not install screens over the vents for any reason. Screens will become
restrictions causing unsafe or inefficient operation.
WARNING
!
PDF created with pdfFactory trial version www.pdffactory.com