EasyManuals Logo

Lab.gruppen PLM Series PLM 10000Q User Manual

Lab.gruppen PLM Series PLM 10000Q
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22 Dolby Lake Controller User Manual PLM Edition Addendum
5.8 Global Events Tab
This is the other tab available in Amplifier Global View.
It provides an Event Log which lists all warnings, faults,
and user actions that have occurred in all devices on
the network since the DLC started. In addition, it will
contain the events that can be read from each PLM’s
internal log covering the 4 hours prior to starting the
DLC PLM Edition software. Various filter options are
available for displaying a user-definable subset of the
log.
Note that the data for the most recent event is repeated
in the separate horizontal pane at the bottom of the
table.
5.8.1 Log Entities
Seven items of information per event are displayed
in the log in tabular form, as follows:
Event The Event column displays any system
fault or warning notifications that occur. Icons
shown below reference the source of the
notification; icons change color, from yellow
(warning) to red (fault) to indicate severity.
Speaker: Warning
Speaker: Fault
Amplifier: Warning
Amplifier: Fault
User Event
Figure 5.8.1: Events tab warning icons
Figure 5.8: Global events logging tab
5 operation

Other manuals for Lab.gruppen PLM Series PLM 10000Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen PLM Series PLM 10000Q and is the answer not in the manual?

Lab.gruppen PLM Series PLM 10000Q Specifications

General IconGeneral
Output Power (per channel at 2 ohms)2500 W
Output Power (per channel at 4 ohms)2300 W
Output Power (per channel at 8 ohms)1250 W
Output Power (per channel at 16 ohms)625 W
Total Output Power10000 W
Number of channels4
Sample Rate96 kHz
Latency1.5 ms
THD+N<0.1%
Damping Factor> 500
Dimensions88 x 483 x 396 mm
Coolingfront-to-rear airflow
ProtectionDC, thermal, short circuit
ConnectorsSpeakON
Voltage100-240 V AC
Signal to Noise Ratio>112 dBA
Input Impedance20k ohms (balanced), 10k ohms (unbalanced)