2.0 LUBRICATION
2.1 RECOMMENDED LUBRICANT
2.1.1 HYDRAULIC FLUIDS
Minimum requirement for hydraulic oil:
Viscosity of 320 cSt at 104
o
F (40
o
C) and 6.4 cSt
at 212
o
F (100
o
C).
Must contain anti-wear, and anti-foam additives,
rust and oxidation neutralizers and self protecting
agents.
Must meet MIL-H-5606 or SAE IOW “MS”
standards. The following oils may be used in the
Optimizer.
Shell Tellus 32 or T-32
2.1.2 MOTOR OIL FOR VEHICLE
Refer to chassis manufaturer’s maintenance
manual.
2.1.3 GREASE
Any lithium-base commercial multi-purpose
grease may be used.
*For Nordic regions Shell Tellus T32 is strongly
recommended.
DO NOT MIX DIFFERENT BRAND
OF OILS IN DOUBT DRAIN AND
REFILL WITH NEW OIL.
CAUTION
The hydraulic tank has a maximum capacity of
81 US gallons or 300 litres. FILL THE
HYDRAULIC TANK TO 80% OF ITS FULL
CAPACITY(Around 65 US Gallons or 240 liters)
IN ORDER TO PREVENT OIL SPILL. Refer to
section 4.