EasyManuals Logo
Home>Lamtec>Controller>FMS Series

Lamtec FMS Series User Manual

Lamtec FMS Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Table of Contents
3
Instrumentation for commissioning 72
O regulation 49 - 62
2
Adjusting load ratings individually 73
Automatic functions control
Entering an initial curve 73
during operation 49 - 50
Approaching control elements from one side 74
Adjusting the integrated O regulator (optional) 49
2
Entering settings 74
Checks during burner start-up 49
Entering top setting 74
O monitoring bands 49
2
Ignition delay when setting 74
O boundary curves 49
2
Pre-setting load automatically 74
Dynamic probe test 50
Entering the compound curves
Probe blockage 50
with the burner stationary 75
Correction output monitoring 50
Keeping the re-circulation damper
Regulation strategy 51 - 53
closed in pre-ventilation 75
With pre-setting for load changes 52
Setting the pilot burner (servicing mode) 75
Extended regulation strategy (air shortage) 53
Switching the burner on again
via the target value 75
Connection to O meter 54
2
Via analogue interface 54
Operator controls and display 55 - 56
System Operation 76 - 89
Mode switching 55
Mode display 76 - 78
Calling up O regulation text messages 56
2
Significance of modes on the FMS 76 - 77
O regulator modes 77
Commissioning 57 - 61
2
"ES" Mode progress (set-control) 78
Setting the correction range 57
Continue programming 78
Inputting the O target value curve 58
2
Calling up the correction range set 59
Calculation and setting of
4 Curve sets FMS (option) 79
control parameters-(manual) 59
Interconnection with 4 curve sets option 79
Lag time (parameters 898/900) 60
P-factor (parameter 899) 60
Checksums
Setting base value for "Deactivated
Running time meter 80
control” and "Air shortage” 61
Recalling the checksums
Calling up the base value for O regulation
2
and the safety times 80
deactivated/air shortage 61
Calling up running time meter 80
Automatic 61
Operation 62
Messages / Faults 81 - 89
The meaning of the additional modes 62
What happens in the event of FMS fault 81
Calling up O regulation text messages 62
2
Reading off a fault 81
Resetting a fault 81
Correction 63 - 66
Calling up fault history 81
Set correction input 63 - 65
O regulation perturbed 82
2
Setting the correction range 65
Air shortage perturbation 82
Recall set correction range 65
Resetting O errors 82
2
Altering the correction range 66
Calling up O regulation error history 82
2
Correction modes 66
Fault codes 83 - 89
Run to shut-off limits 67 - 70
FMS Fault Correction
Run to shut-off limits 67
Aids 90 - 115
Checking the shut-off limits at the
General Faults (A) 90 - 94
three/point step output of the FMS 67
Three-point step control output (B) 95 - 96
Checking the shut-off limits at
continuous output of the FMS 68
Continuous output (C) 97
Tolerance limits direction air deficiency 69
Load signal (D) 98 - 99
Indication for an example protocol 69
Feedback (E) 100 - 103
Checking the O influence 69
2
Correction input (F) 104 - 105
Example protocol 70
Digital inputs (G) 106
Control unit faults (H) 107
Tips & Tricks 71 - 75
Leakage test 108
Programming 1st point
(ignition load point) 71
Parameters (P) 109 - 118
Programming with burner running 71 - 72
Programming with burner stationary 72
Reversing the programming 72

Table of Contents

Other manuals for Lamtec FMS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lamtec FMS Series and is the answer not in the manual?

Lamtec FMS Series Specifications

General IconGeneral
BrandLamtec
ModelFMS Series
CategoryController
LanguageEnglish

Related product manuals