April 8, 2011 HN FAQ Memo, Version 2.0 Page 62 of 108
3.3.7 C200 parameters from diff. HN Farms.
Table A: C200 parameters from Tange Skov gård (TSG) 20. oktober 2009
Nr.
Funktion
Range
Unit
Default
TSG
P1
Flushing pulse, Water
1-120
Sec.
10
25
P2
Flushing pulse, Air
1-120
Sec.
10
45
P3
Blowing after prerinse
0-15
Min.
3
4
P4
Blowing after middle phases
0-15
Min.
4
4
P5
Blowing after final phase
0-15
Min.
6
6
1
P10
Temp. Limit return water
25-113
°C
40
38
P11
Temp Limit outgoing water.
50-185
°C
70
82
P15
Node adress
5-125
-
75
75
P16
Versionnumber
Kun læs
-
-
1.12
P17
Min. time circulation cleaning.
4-45
Min.
8
12
P22
External air injection delay
0-120
Sec.
30
20
P23
Extra flushing pulse air time (trombone)
0.5-60.0
Sec.
1
2.2
P28
Acid/desinfection circulation (cleaning time)
0-15
Min.
8
15
P29
Pulse after blowing air time ON
0-60
Sec.
0
0
2
P30
Pulse after blowing air time OFF
0-60
sec.
0
0
2
P50
Cleaning program
-
-
1
2
P54
Heater
-
-
0
1
P58
ALCOM-bus
-
-
0
1
1
Should possible be increased to 8.
2
Must not be0, in order to dry the HN
Table B: C200 parameters on Hanninggård HNG 1. december 2009
Nr.
Funktion
Range
Unit
Default
HNG
P1
Flushing pulse, Water
1-120
Sec.
10
25
P2
Flushing pulse, Air
1-120
Sec.
10
45
P3
Blowing after prerinse
0-15
Min.
3
4
P4
Blowing after middle phases
0-15
Min.
4
4
P5
Blowing after final phase
0-15
Min.
6
8
P10
Temp. Limit return water
25-113
°C
40
?
P11
Temp Limit outgoing water.
50-185
°C
70
?
P15
Node adress
5-125
-
75
75
P16
Versionnumber
Kun læs
-
-
1.12
P17
Min. time circulation cleaning.
4-45
Min.
8
15
P22
External air injection delay
0-120
Sec.
30
15
P23
Extra flushing pulse air time (trombone)
0.5-60.0
Sec.
1
2.0
P28
Acid/desinfection circulation (cleaning time)
0-15
Min.
8
15
P29
Pulse after blowing air time ON
0-60
Sec.
0
10
P30
Pulse after blowing air time OFF
0-60
sec.
0
10
P50
Cleaning program
-
-
1
2