Proline Low-temperature Thermostats
110 Interfaces - Modules YACE0072 / 21.08.07
8.4.1 Menu structure Analogue module (Master)
All existing menu points are illustrated. However, the Master unit masks out menu points which cannot
be executed.
1%21
Actual bath temperature
or actual value of
external temperature
LMnet Configure
modules
LM rR : Take setpoint
temperature from input
LM rD: Take external actual
temperature from input
LM OO : Take pump power (0-
100%) from input
LM rB : Output controlled
temperature (internal / external
Pt / ext. analogue /ext. serial)
on output
LM X : Output actuating signal
Y on output
LM OO : Output pump power (0-
100%) on output
LMrDl : Output pump speed (0-
100%) on output
LM rR : Output setpoint
temperature on output
LMrDO : Output ext. act.
temperature from Pt100 on
LMrD@ : Output ext. act.
temperature from analogue
input
LMrDR : Output ext. actual
temperature from serial
interface on output
LM r0 : Output internal actual
temperature on output
RgmYW
Display level
@01--
Set Input 2
@/0--
Set Output 1
@/1--
Set Output 2
@00--
Set Input 1
B@K-- Calibrate
inputs and outputs
cDE Restore
factory settings
Dlc
Quit menu
@lA-- Configure
analo
g
ue module
LM XX: Set input/output
mode
rXO 0 or T: Current (0) or
voltage (T) input/output
0 <1/ or $1/: Current input/
output 0-20 or 4-20 mA
G 0/</: Set maximum value
c of the input/output
TRD / or0: Activate (0);
deactivate (/) input /output
K </: Set minimum value
d of input/output
Dlc
Quit settings level
B@0‘T : Calibrate voltage
Input 2
B@0!0 : Calibrate current
Input 1
B@0!T : Calibrate voltage
Input 1
B@0‘0 : Calibrate current
Input 2
B@/!T : Calibrate voltage
Output 1
B@/!0 : Calibrate current
Output 1
B@/‘0 : Calibrate current
Output 2
B@/‘T : Calibrate voltage
Output 2
Dlc
Quit calibration level
TDp : Display module software
version
@00 0 : Current on Analogue
Input 1, (if current active)
@00 T : Voltage on Analogue
Input 1, (if voltage active)
@01 0 : Current on Analogue
Input 2, (if current active)
@01 T : Voltage on Analogue
Input 2, (if voltage active)
@/0 0 : Setpoint curr. on
Analogue Output 1, (if current
active
)
@/0 T : Setpoint volt. on
Analogue Output 1, (if volt.
@/1 0 : Setpoint curr. on
Analogue Output 2, (if current
active
)
@/1 T : Setpoint volt. on
Analogue Output 2, (if volt.
T13 : Display 24V supply
voltage
Rlp^G : Module serial number
Places 1-5
Dlc
Quit calibration level
Rlp^K : Module serial number
Places 6-10
c corresponds to 20mA or 10V
d corresponds to 0mA, 4mA or 0V