5) Accessories
Aerial (ANT)
Input for the connection of a radio receiver aerial.
6) Definition of optical signals
DL1 - Programming Led (red): It switches on in programming step and during gate motion.
DL2 - Net Led (green): It switches on with 20Vac power on the input VIN.
DL3 - Pedestrian start Led (green): It switches on at a pedestrian start control in terminal board.
DL4 - Start Led (green): It switches on at a start control in terminal board.
DL5 - Stop Led (red): It switches off at a stop control in terminal board.
DL6 - Photocell Led (yellow): It switches off when the photocell is darkened.
DL7 - Photostop Led (yellow): It switches off when the photoelectric cell is darkened.
DL8 - Opening stroke end Led M1 (yellow): It switches off when the opening stroke end for motor 1 is activated.
DL9 - Closing stroke end Led M1 (yellow): It switches off when the closing stroke end for motor 1 is activated.
DL10 - Opening stroke end Led M2 (yellow): It switches off when the opening stroke end for motor 2 is activated.
DL11 - Closing stroke end Led M2 (yellow): It switches off when the closing stroke end for motor 2 is activated.
7) Definition of trimmer
RV1 – Amperometric regulation
It regulates the intervention threshold of amperometric sensor during fast speed.
8) Definition of dip switches and jumpers (selection of working logic)
Dip switch 1 (working with automatic closing in Step-by-Step logic)
ON =Step-by-Step with automatic closing off=Step-by-Step without automatic closing
Dip switch 2 (working with Condominium or Step-by-Step logic)
ON=
Step-by-Step off= Condominium
Dip switch 3 (working with immediate closing in Step-by-Step logic)
ON = Step-by-Step with immediate closing off = Step-by-Step without immediate closing
Dip switch 4 (working with extra-push)
ON= It enables extra-push off= It disables extra-push
Dip switch 5 (Phase displacement zero setting)
ON = The two wings open and close in the meantime off = The wing M1 is delayed in opening while the wing M2 is delayed in closing
ENGLISH

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leb Electronics CTR50 and is the answer not in the manual?

Leb Electronics CTR50 Specifications

General IconGeneral
BrandLeb Electronics
ModelCTR50
CategoryController
LanguageEnglish

Related product manuals