Radio receiver
The control board CTR50 contains a 2 channels radio receiver. The radio receiver can memorize up to 100 codes and can work with remote
controls Fixed Code, Rolling Code or in Secret Key environment. The channel 1 of radio receiver acts as Start, while the channel 2 acts as pedestrian
Start.
Extra-push (dip switch 4 = ON)
It is possible to enable the “extra-pushfunction, used to make easy the release of electric lock in bad weather conditions, such as wind, ice, etc. The
“extra-push” function operates but with closed gate and is a logical sequence starting the electric lock during a short closing step (1 sec.
about) and disables it only after the wing’s start in opening. At closing end the unit supplies a short acceleration on both wings (1,5 sec) at the
maximum speed so to make easy the electric lock’s insertion.
Void phase displacement
Putting the Dip switch 5 in ON, any phase displacement between the two wings is set at zero. The two wings open and close in the same time.
13) Working logic
Working with “Step-by-Step” logic (Dip 1 = OFF Dip 2 = ON)
A Start control puts into motion, a following control stops the motion, a further Start control reverses the motion (direction reverse). A Stop control
stops the motion. After a Stop, a Start control starts the motion in opening.
Working with “Automatic closing” (Dip 1 = ON Dip 2 = ON)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied during the pause interrupts work cycle
and the gate doesn’t close automatically. Photocell intervention during pause time reloads it, extending the period before automatic closing. A stop
control supplied during pause time interrupts work cycle.
Working with “Condominium” logic (Dip 1 = irrelevant Dip 2 = OFF Dip 3 = irrelevant)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied while opening is irrelevant. A Start
control supplied while closing provokes the stop and gear reverse after 1,5 sec. about. A Start control or photocell intervention during pause time
reloads it, extending the period before automatic closing. A stop control supplied during pause time interrupts work cycle.
WARNING: The modification of working logic can be set only after having switched off and then switched on again the unit.
Working with “Immediate closing” (Dip 3 = ON Dip 2 = ON)
In opening step and in pause time, after having passed the photocell, it determines the stop and, after 1,5 sec., gate closing.
Electric power lack
Following to a temporary electric power lack, at recovery the first Start control puts in action opening motion.
Opening with Timer
If the gate opening is controlled by a Timer it is necessary to enable the Condominium working logic.
Working with single wing (Dip 5 = ON)
In single wing working the above mentioned working logics remain the same.
The wing is to be compulsory connected to motor M2.
ENGLISH

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leb Electronics CTR50 and is the answer not in the manual?

Leb Electronics CTR50 Specifications

General IconGeneral
BrandLeb Electronics
ModelCTR50
CategoryController
LanguageEnglish

Related product manuals