27
D) MAINTENANCE
Warning: The maintenance of the device is to be carried out only and exclusively by a specialized technician authorized from the Manufacturer.
Any operation of maintenance or control of the device must be carried out without power supply.
Ordinary maintenance: Every time that it is necessary and however every 6 months it is recommended to verify the device working.
Extraordinary maintenance: In case of failure, remove the device and send it for repair to the manufacturer’s laboratory or to an authorized
laboratory.
The Manufacturer is not responsible for missing observance of rules above described.
E) DECLARATION OF CONFORMITY
Description of the unit: Electronic board for the control of 2 motors supplied with 24Vdc voltage intended for the automation of a
gate.
Model: CTR50
Applied rules: EN 61000-6-3, EN 61000-6-1, EN 301489-1, EN 301489-3, EN 300220-2, EN 300220-1, EN 60950-1
Test laboratory : NEMKO SPA
Outcome: Positive
The manufacturer declares that the above listed products comply with rules provided for by European directives 2004/108/EC and 2006/95/EC.
Date: 22-02-2018
F) Remote control Entry/Cancellation
Learning of remote controls (START code)
To enter a START code, press the key P1 for 1 sec., Led DL1 issues a short flash and then it lights up with a steady light,
Then press the key on the remote control to be memorized. Led DL1 will switch off, signalling that the code has been memorized. End of
procedure. Note: In case of failed recognition, Led DL1 keeps switched on for 10 sec., then it will automatically switch off.
Learning of remote controls (PEDESTRIAN START code)
To enter a PEDESTRIAN START code, press the key P1 for 1 sec., Led DL1 issues a short flash,
Without hesitation, press again the key P1 for 1 sec., Led DL1 issues a short flash and then it lights up with a steady light,
Then press the key on the remote control to be memorized. Led DL1 will switch off, signalling that the code has been memorized. End of
procedure. Note: In case of failed recognition, Led DL1 keeps switched on for 10 sec., then it will automatically switch off.
Cancellation of a memorized code
Press the key P2 for 1 sec., Led DL1 will switch on with a steady light. Press the key to be cancelled on the remote control, Led DL1 will switch off,
signalling that the code has been cancelled. End of procedure.
Cancellation of all memorized codes (total dump)
Keep pressed the key P2 for approx. 10 sec. until the Led DL1 issues a short flash. End of procedure.