Terminal board J2
Terminal 1 - Common power supply for all electric contacts
Terminal 2 - Electric contact N.O. of pedestrian start button
Terminal 3 - Electric contact N.O. of start button
Terminal 4 - Common terminal for all electric contacts
Terminal 5 - Electric contact N.C. of stop button
Terminal 6 - Electric contact N.C. of the photocell
Terminal 7 - Common terminal for all electric contacts
Terminal 8 - Electric contact N.C. of the photostop
Terminal 9 - Connection for open gate lamp
Terminal 10 - Connection for open gate lamp
Important: The normally closed inputs not in use must be fitted with jumpers.
Terminal board J1
Terminal 1 - Positive photocell 12Vdc power supply
Terminal 2 - Negative photocell 12Vdc power supply
Terminal 3 - Positive blinker 12Vdc power supply
Terminal 4 - Negative blinker 12Vdc power supply
Warning : The polarities of power voltage supply are to be strictly respected.
Terminal 5 - Power supply for motor M1
Terminal 6 - Power supply for motor M1
Terminal 7 - Power supply for motor M2
Terminal 8 - Power supply for motor M2
Terminal 9 - Electric lock power supply
Terminal 10 - Electric lock power supply
Terminal board J3
Terminal 1 - Electric contact N.C. of opening stroke end for motor 1
Terminal 2 - Electric contact N.C. of closing stroke end for motor 1
Terminal 3 - Electric contact of safety side for motor 1
Terminal 4 - Common terminal for all electric contacts
Terminal 5 - Electric contact N.C. of opening stroke end for motor 2
Terminal 6 - Electric contact N.C. of closing stroke end for motor 2
Terminal 7 - Electric contact of safety side for motor 2
Terminal 8 - Common terminal for all electric contacts
Notice: The inputs of safety sides normally closed not in use must be fitted with jumpers.