EasyManuals Logo

Leb Electronics CTR50 User Manual

Default Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
26
Terminal board J2
Terminal 1 - Common power supply for all electric contacts
Terminal 2 - Electric contact N.O. of pedestrian start button
Terminal 3 - Electric contact N.O. of start button
Terminal 4 - Common terminal for all electric contacts
Terminal 5 - Electric contact N.C. of stop button
Terminal 6 - Electric contact N.C. of the photocell
Terminal 7 - Common terminal for all electric contacts
Terminal 8 - Electric contact N.C. of the photostop
Terminal 9 - Connection for open gate lamp
Terminal 10 - Connection for open gate lamp
Important: The normally closed inputs not in use must be fitted with jumpers.
Terminal board J1
Terminal 1 - Positive photocell 12Vdc power supply
Terminal 2 - Negative photocell 12Vdc power supply
Terminal 3 - Positive blinker 12Vdc power supply
Terminal 4 - Negative blinker 12Vdc power supply
Warning : The polarities of power voltage supply are to be strictly respected.
Terminal 5 - Power supply for motor M1
Terminal 6 - Power supply for motor M1
Terminal 7 - Power supply for motor M2
Terminal 8 - Power supply for motor M2
Terminal 9 - Electric lock power supply
Terminal 10 - Electric lock power supply
Terminal board J3
Terminal 1 - Electric contact N.C. of opening stroke end for motor 1
Terminal 2 - Electric contact N.C. of closing stroke end for motor 1
Terminal 3 - Electric contact of safety side for motor 1
Terminal 4 - Common terminal for all electric contacts
Terminal 5 - Electric contact N.C. of opening stroke end for motor 2
Terminal 6 - Electric contact N.C. of closing stroke end for motor 2
Terminal 7 - Electric contact of safety side for motor 2
Terminal 8 - Common terminal for all electric contacts
Notice: The inputs of safety sides normally closed not in use must be fitted with jumpers.
Faston FS1 - Positive pole connection of buffer battery
Faston FS2 - Negative pole connection of buffer battery
Important: Make sure of the correct positioning of the jumper JP2 - page 24
ENGLISH

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leb Electronics CTR50 and is the answer not in the manual?

Leb Electronics CTR50 Specifications

General IconGeneral
BrandLeb Electronics
ModelCTR50
CategoryController
LanguageEnglish

Related product manuals