Group 2 Safety Page 21
JET2 neo Release R1.07 en
Ventilation in the hydraulic cabinet
HV-cutoff at creepage current
Plastic containers are arranged in the
field of metal surfaces (PE-potential)
HV- and ink cutoff as well as nozzle
sealing at HV-flashovers
2.9 Safety measures at the place of installation
Mains connection!
The device has no mains switch and must only be connected to a easy
accessible plug socket in the direct vicinity of the place of setting up!
I
nstallation of the device
The device must be installed in a well ventilated room only and must be
kept away from any source of heat, flame or sparks, e.g. radiant
heater, etc.
Caution
– Danger of explosion!
The device should be only operated outside of explosive areas!
The installation has to be carried out according to the installation
instructions of the manufacturer!
The device has to be integrated in the lightning protection concept
of the operator!
Precautions regarding electrostatics have to be carried out!
A place of setting up must be selected with sufficient load bearing
capacity and stability. When setting up it must be observed that
sufficient movement space is available for the operating and service
personnel. Solvents are processed in the device, sufficient room
ventilation must be ensured!
Prior to assembly the place of setting up must be cleaned of dirt and
contamination (residue of lubricants etc.). The working place
surroundings should be kept clean at all times in order to ensure
unrestricted access to the LEIBINGER JET2 neo device.