Page 34 Transport/Start up Group 5
Release R1.07 en JET2 neo
Please note, that the grounding point (6) is hidden behind the round
grounding
label (7) on the lower left hand side of the cabinet
of the printer
Grounding schematic and grounding point
2 – Installation (machine)
A separate grounding line (min. cable cross-section 2.00 mm
2
) to the printer
cabinet must be installed before
the print head is mounted in the installation and
before the printer is plugged to the power supply.
The connection must be carried with a solid bonding that corresponds with
existing guidelines.
Annotation: A suitable grounding cable is available optionally (accessories).
The installation (machine) and the printer must have the same potential/ground.